The store will not work correctly when cookies are disabled.
JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Solid State Drives (SSD)
Hard drive SSD capacity 32 GB Memory type MLC Data transmission Read speed 260 MB/s Write speed 40 MB/s Random write (4KB) 10500 IOPS Random read (4KB) 25000 IOPS Data transfer rate 6 Gbit/s Performance Interface Serial ATA III Component for Server/workstation Controller type Marvell 88SE9230 SSD capacity 32 GB Read speed 260 MB/s Write speed 40 MB/s Memory type MLC Random write (4KB) 10500 IOPS Random read (4KB) 25000 IOPS Data transfer rate 6 Gbit/s Design Component for Server/workstation SSD form factor M.2 Features Interface Serial ATA III Component for Server/workstation Controller type Marvell 88SE9230 SSD capacity 32 GB Read speed 260 MB/s Write speed 40 MB/s Memory type MLC Random write (4KB) 10500 IOPS Random read (4KB) 25000 IOPS Data transfer rate 6 Gbit/s SSD form factor M.2 Harmonized System (HS) code 84717070 Technical details Interface Serial ATA III SSD form factor M.2 Weight & dimensions Width 22 mm Weight 5 g Depth 42 mm Logistics data Harmonized System (HS) code 84717070
Lenovo 7N47A00129 internal solid state drive M.2 32 GB Serial ATA III MLC Hard drive SSD capacity 32 GB Memory type MLC Data transmission Read speed 260 MB/s Write speed 40 MB/s Random write (4KB) 10500 IOPS Random read (4KB) 25000 IOPS Data transfer rate 6 Gbit/s Performance Interface Serial ATA III Component for Server/workstation Controller type Marvell 88SE9230 SSD capacity 32 GB Read speed 260 MB/s Write speed 40 MB/s Memory type MLC Random write (4KB) 10500 IOPS Random read (4KB) 25000 IOPS Data transfer rate 6 Gbit/s Design Component for Server/workstation SSD form factor M.2 Features Interface Serial ATA III Component for Server/workstation Controller type Marvell 88SE9230 SSD capacity 32 GB Read speed 260 MB/s Write speed 40 MB/s Memory type MLC Random write (4KB) 10500 IOPS Random read (4KB) 25000 IOPS Data transfer rate 6 Gbit/s SSD form factor M.2 Harmonized System (HS) code 84717070 Technical details Interface Serial ATA III SSD form factor M.2 Weight & dimensions Width 22 mm Weight 5 g Depth 42 mm Logistics data Harmonized System (HS) code 84717070
£70.31
£58.59 In stock
Hard drive SSD capacity 512 GB Performance Interface PCI Express Component for Server/workstation NVMe Yes SSD capacity 512 GB Design Component for Server/workstation SSD form factor M.2 Features Interface PCI Express Component for Server/workstation NVMe Yes SSD capacity 512 GB SSD form factor M.2 Harmonized System (HS) code 84717070 Technical details Interface PCI Express SSD form factor M.2 Logistics data Harmonized System (HS) code 84717070
DELL JPM37 internal solid state drive M.2 512 GB PCI Express NVMe Hard drive SSD capacity 512 GB Performance Interface PCI Express Component for Server/workstation NVMe Yes SSD capacity 512 GB Design Component for Server/workstation SSD form factor M.2 Features Interface PCI Express Component for Server/workstation NVMe Yes SSD capacity 512 GB SSD form factor M.2 Harmonized System (HS) code 84717070 Technical details Interface PCI Express SSD form factor M.2 Logistics data Harmonized System (HS) code 84717070
£186.62
£155.52 Out of stock
Hard drive SSD capacity 250 GB Data transmission Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Data transfer rate 6 Gbit/s Endurance Mean time between failures (MTBF) 1750000 h Certificates Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco Performance Interface Serial ATA III Component for PC/Laptop TBW rating 100 SSD capacity 250 GB Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Design Component for PC/Laptop Product colour Black Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor 2.5" Features Interface Serial ATA III Component for PC/Laptop TBW rating 100 SSD capacity 250 GB Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor 2.5" Harmonized System (HS) code 84717070 Power Power consumption (write) 2.25 W Power consumption (read) 2.2 W Operational conditions Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Technical details Interface Serial ATA III Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Product colour Black SSD form factor 2.5" Weight & dimensions Width 69.8 mm Weight 37.4 g Height 7 mm Depth 100.2 mm Logistics data Harmonized System (HS) code 84717070 Other features Product colour Black
Western Digital Blue 3D 2.5" 250 GB Serial ATA III Hard drive SSD capacity 250 GB Data transmission Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Data transfer rate 6 Gbit/s Endurance Mean time between failures (MTBF) 1750000 h Certificates Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco Performance Interface Serial ATA III Component for PC/Laptop TBW rating 100 SSD capacity 250 GB Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Design Component for PC/Laptop Product colour Black Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor 2.5" Features Interface Serial ATA III Component for PC/Laptop TBW rating 100 SSD capacity 250 GB Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor 2.5" Harmonized System (HS) code 84717070 Power Power consumption (write) 2.25 W Power consumption (read) 2.2 W Operational conditions Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Technical details Interface Serial ATA III Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Product colour Black SSD form factor 2.5" Weight & dimensions Width 69.8 mm Weight 37.4 g Height 7 mm Depth 100.2 mm Logistics data Harmonized System (HS) code 84717070 Other features Product colour Black
£64.09
£53.41 In stock
Hard drive SSD capacity 250 GB Data transmission Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Data transfer rate 6 Gbit/s Endurance Mean time between failures (MTBF) 1750000 h Features Component for PC/Laptop TBW rating 100 SSD capacity 250 GB Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor M.2 Harmonized System (HS) code 84717070 Power Power consumption (write) 2.25 W Power consumption (read) 2.2 W Certificates Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco Performance Component for PC/Laptop TBW rating 100 SSD capacity 250 GB Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Design Component for PC/Laptop Product colour Black Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor M.2 Weight & dimensions Width 22 mm Weight 7 g Height 2.38 mm Depth 80 mm Operational conditions Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Technical details Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Product colour Black SSD form factor M.2 Other features Product colour Black Logistics data Harmonized System (HS) code 84717070
Western Digital Blue 3D 250 GB M.2 Hard drive SSD capacity 250 GB Data transmission Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Data transfer rate 6 Gbit/s Endurance Mean time between failures (MTBF) 1750000 h Features Component for PC/Laptop TBW rating 100 SSD capacity 250 GB Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor M.2 Harmonized System (HS) code 84717070 Power Power consumption (write) 2.25 W Power consumption (read) 2.2 W Certificates Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco Performance Component for PC/Laptop TBW rating 100 SSD capacity 250 GB Read speed 550 MB/s Write speed 525 MB/s Random write (4KB) 81000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Design Component for PC/Laptop Product colour Black Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor M.2 Weight & dimensions Width 22 mm Weight 7 g Height 2.38 mm Depth 80 mm Operational conditions Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Technical details Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Product colour Black SSD form factor M.2 Other features Product colour Black Logistics data Harmonized System (HS) code 84717070
£51.67
£43.06 In stock
Hard drive SSD capacity 500 GB Data transmission Read speed 560 MB/s Write speed 530 MB/s Random write (4KB) 84000 IOPS Random read (4KB) 95000 IOPS Data transfer rate 6 Gbit/s Endurance Mean time between failures (MTBF) 1750000 h Features Interface Serial ATA III Component for PC/Laptop TBW rating 200 SSD capacity 500 GB Read speed 560 MB/s Write speed 530 MB/s Random write (4KB) 84000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor 2.5" Harmonized System (HS) code 84717070 Power Power consumption (write) 3.35 W Power consumption (read) 2.05 W Certificates Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco Performance Interface Serial ATA III Component for PC/Laptop TBW rating 200 SSD capacity 500 GB Read speed 560 MB/s Write speed 530 MB/s Random write (4KB) 84000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Design Component for PC/Laptop Product colour Black Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor 2.5" Weight & dimensions Width 69.8 mm Weight 37.4 g Height 7 mm Depth 100.2 mm Operational conditions Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Technical details Interface Serial ATA III Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Product colour Black SSD form factor 2.5" Other features Product colour Black Logistics data Harmonized System (HS) code 84717070
Western Digital Blue 3D 500 GB 2.5" Serial ATA III Hard drive SSD capacity 500 GB Data transmission Read speed 560 MB/s Write speed 530 MB/s Random write (4KB) 84000 IOPS Random read (4KB) 95000 IOPS Data transfer rate 6 Gbit/s Endurance Mean time between failures (MTBF) 1750000 h Features Interface Serial ATA III Component for PC/Laptop TBW rating 200 SSD capacity 500 GB Read speed 560 MB/s Write speed 530 MB/s Random write (4KB) 84000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor 2.5" Harmonized System (HS) code 84717070 Power Power consumption (write) 3.35 W Power consumption (read) 2.05 W Certificates Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco Performance Interface Serial ATA III Component for PC/Laptop TBW rating 200 SSD capacity 500 GB Read speed 560 MB/s Write speed 530 MB/s Random write (4KB) 84000 IOPS Random read (4KB) 95000 IOPS Mean time between failures (MTBF) 1750000 h Data transfer rate 6 Gbit/s Design Component for PC/Laptop Product colour Black Certification FCC, UL, TUV, KC, BSMI, VCCI, Morocco SSD form factor 2.5" Weight & dimensions Width 69.8 mm Weight 37.4 g Height 7 mm Depth 100.2 mm Operational conditions Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Technical details Interface Serial ATA III Operating temperature (T-T) 0 - 70 °C Storage temperature (T-T) -55 - 85 °C Operating shock 1500 G Operating vibration 5 G Non-operating vibration 4.9 G Product colour Black SSD form factor 2.5" Other features Product colour Black Logistics data Harmonized System (HS) code 84717070
£66.41
£55.34 In stock
Hard drive SSD capacity 960 GB Data transmission Read speed 520 MB/s Write speed 480 MB/s Random write (4KB) 24000 IOPS Random read (4KB) 97000 IOPS Write latency 30 µs Read latency 130 µs Data transfer rate 6 Gbit/s Endurance Mean time between failures (MTBF) 2000000 h Performance Interface Serial ATA III Component for Server/workstation Hot-swap Yes SSD capacity 960 GB Read speed 520 MB/s Write speed 480 MB/s Random write (4KB) 24000 IOPS Random read (4KB) 97000 IOPS Mean time between failures (MTBF) 2000000 h Write latency 30 µs Read latency 130 µs Data transfer rate 6 Gbit/s Design Component for Server/workstation Product colour Black SSD form factor 2.5" Features Interface Serial ATA III Component for Server/workstation Hot-swap Yes SSD capacity 960 GB Read speed 520 MB/s Write speed 480 MB/s Random write (4KB) 24000 IOPS Random read (4KB) 97000 IOPS Mean time between failures (MTBF) 2000000 h Write latency 30 µs Read latency 130 µs Data transfer rate 6 Gbit/s SSD form factor 2.5" Harmonized System (HS) code 84717070 Power Power consumption (write) 3 W Power consumption (read) 3 W Operational conditions Operating shock 1500 G Operating vibration 2.17 G Technical details Interface Serial ATA III Hot-swap Yes Operating shock 1500 G Operating vibration 2.17 G Product colour Black SSD form factor 2.5" Logistics data Harmonized System (HS) code 84717070 Other features Product colour Black
Lenovo 7N47A00113 internal solid state drive 2.5" 960 GB Serial ATA III Hard drive SSD capacity 960 GB Data transmission Read speed 520 MB/s Write speed 480 MB/s Random write (4KB) 24000 IOPS Random read (4KB) 97000 IOPS Write latency 30 µs Read latency 130 µs Data transfer rate 6 Gbit/s Endurance Mean time between failures (MTBF) 2000000 h Performance Interface Serial ATA III Component for Server/workstation Hot-swap Yes SSD capacity 960 GB Read speed 520 MB/s Write speed 480 MB/s Random write (4KB) 24000 IOPS Random read (4KB) 97000 IOPS Mean time between failures (MTBF) 2000000 h Write latency 30 µs Read latency 130 µs Data transfer rate 6 Gbit/s Design Component for Server/workstation Product colour Black SSD form factor 2.5" Features Interface Serial ATA III Component for Server/workstation Hot-swap Yes SSD capacity 960 GB Read speed 520 MB/s Write speed 480 MB/s Random write (4KB) 24000 IOPS Random read (4KB) 97000 IOPS Mean time between failures (MTBF) 2000000 h Write latency 30 µs Read latency 130 µs Data transfer rate 6 Gbit/s SSD form factor 2.5" Harmonized System (HS) code 84717070 Power Power consumption (write) 3 W Power consumption (read) 3 W Operational conditions Operating shock 1500 G Operating vibration 2.17 G Technical details Interface Serial ATA III Hot-swap Yes Operating shock 1500 G Operating vibration 2.17 G Product colour Black SSD form factor 2.5" Logistics data Harmonized System (HS) code 84717070 Other features Product colour Black
£403.78
£336.48 In stock
Hard drive SSD capacity 480 GB Performance Interface Serial ATA SSD capacity 480 GB Design SSD form factor 2.5" Features Interface Serial ATA SSD capacity 480 GB SSD form factor 2.5" Technical details Interface Serial ATA SSD form factor 2.5"
DELL W02FT internal solid state drive 2.5" 480 GB Serial ATA Hard drive SSD capacity 480 GB Performance Interface Serial ATA SSD capacity 480 GB Design SSD form factor 2.5" Features Interface Serial ATA SSD capacity 480 GB SSD form factor 2.5" Technical details Interface Serial ATA SSD form factor 2.5"
£254.84
£212.37 In stock
Hard drive SSD capacity 400 GB Data transmission Data transfer rate 12 Gbit/s Performance Interface SAS Component for Server/workstation SSD capacity 400 GB Data transfer rate 12 Gbit/s Compatible products ProLiant DL560 Gen10 D2500sb ProLiant DL325 Gen10 Design Component for Server/workstation Product colour Aluminium, Black SSD form factor 2.5" Features Interface SAS Component for Server/workstation SSD capacity 400 GB Data transfer rate 12 Gbit/s SSD form factor 2.5" Compatible products ProLiant DL560 Gen10 D2500sb ProLiant DL325 Gen10 Technical details Interface SAS Product colour Aluminium, Black SSD form factor 2.5" Other features Product colour Aluminium, Black
HPE 872505-001 internal solid state drive 2.5" 400 GB SAS Hard drive SSD capacity 400 GB Data transmission Data transfer rate 12 Gbit/s Performance Interface SAS Component for Server/workstation SSD capacity 400 GB Data transfer rate 12 Gbit/s Compatible products ProLiant DL560 Gen10 D2500sb ProLiant DL325 Gen10 Design Component for Server/workstation Product colour Aluminium, Black SSD form factor 2.5" Features Interface SAS Component for Server/workstation SSD capacity 400 GB Data transfer rate 12 Gbit/s SSD form factor 2.5" Compatible products ProLiant DL560 Gen10 D2500sb ProLiant DL325 Gen10 Technical details Interface SAS Product colour Aluminium, Black SSD form factor 2.5" Other features Product colour Aluminium, Black
£514.24
£428.53 In stock
Hard drive SSD capacity 960 GB Data transmission Random write (4KB) 52500 IOPS Random read (4KB) 60000 IOPS Write latency 40 µs Read latency 130 µs Data transfer rate 6 Gbit/s Performance Interface Serial ATA III Component for Server/workstation SSD capacity 960 GB Random write (4KB) 52500 IOPS Random read (4KB) 60000 IOPS Write latency 40 µs Read latency 130 µs Data transfer rate 6 Gbit/s Design Component for Server/workstation Product colour Aluminium, Black SSD form factor 2.5" Features Interface Serial ATA III Component for Server/workstation SSD capacity 960 GB Random write (4KB) 52500 IOPS Random read (4KB) 60000 IOPS Write latency 40 µs Read latency 130 µs Data transfer rate 6 Gbit/s SSD form factor 2.5" Technical details Interface Serial ATA III Product colour Aluminium, Black SSD form factor 2.5" Other features Product colour Aluminium, Black
HPE 875474-B21 internal solid state drive 2.5" 960 GB Serial ATA III Hard drive SSD capacity 960 GB Data transmission Random write (4KB) 52500 IOPS Random read (4KB) 60000 IOPS Write latency 40 µs Read latency 130 µs Data transfer rate 6 Gbit/s Performance Interface Serial ATA III Component for Server/workstation SSD capacity 960 GB Random write (4KB) 52500 IOPS Random read (4KB) 60000 IOPS Write latency 40 µs Read latency 130 µs Data transfer rate 6 Gbit/s Design Component for Server/workstation Product colour Aluminium, Black SSD form factor 2.5" Features Interface Serial ATA III Component for Server/workstation SSD capacity 960 GB Random write (4KB) 52500 IOPS Random read (4KB) 60000 IOPS Write latency 40 µs Read latency 130 µs Data transfer rate 6 Gbit/s SSD form factor 2.5" Technical details Interface Serial ATA III Product colour Aluminium, Black SSD form factor 2.5" Other features Product colour Aluminium, Black
£492.32
£410.27 In stock
Hard drive SSD capacity 480 GB Data transmission Random write (4KB) 52500 IOPS Random read (4KB) 62000 IOPS Write latency 40 µs Read latency 125 µs Data transfer rate 6 Gbit/s Performance Interface Serial ATA III Component for Server/workstation SSD capacity 480 GB Random write (4KB) 52500 IOPS Random read (4KB) 62000 IOPS Write latency 40 µs Read latency 125 µs Data transfer rate 6 Gbit/s Design Component for Server/workstation Product colour Aluminium, Black SSD form factor 2.5" Features Interface Serial ATA III Component for Server/workstation SSD capacity 480 GB Random write (4KB) 52500 IOPS Random read (4KB) 62000 IOPS Write latency 40 µs Read latency 125 µs Data transfer rate 6 Gbit/s SSD form factor 2.5" Technical details Interface Serial ATA III Product colour Aluminium, Black SSD form factor 2.5" Other features Product colour Aluminium, Black
HPE 875470-B21 internal solid state drive 2.5" 480 GB Serial ATA III Hard drive SSD capacity 480 GB Data transmission Random write (4KB) 52500 IOPS Random read (4KB) 62000 IOPS Write latency 40 µs Read latency 125 µs Data transfer rate 6 Gbit/s Performance Interface Serial ATA III Component for Server/workstation SSD capacity 480 GB Random write (4KB) 52500 IOPS Random read (4KB) 62000 IOPS Write latency 40 µs Read latency 125 µs Data transfer rate 6 Gbit/s Design Component for Server/workstation Product colour Aluminium, Black SSD form factor 2.5" Features Interface Serial ATA III Component for Server/workstation SSD capacity 480 GB Random write (4KB) 52500 IOPS Random read (4KB) 62000 IOPS Write latency 40 µs Read latency 125 µs Data transfer rate 6 Gbit/s SSD form factor 2.5" Technical details Interface Serial ATA III Product colour Aluminium, Black SSD form factor 2.5" Other features Product colour Aluminium, Black
£248.38
£206.98 In stock
Hard drive SSD capacity 256 GB Memory type TLC Data transmission Read speed 540 MB/s Write speed 500 MB/s Random write (4KB) 88000 IOPS Random read (4KB) 97000 IOPS Data transfer rate 6 Gbit/s Performance Interface Serial ATA III Component for PC NAND flash type TLC (Triple Level Cell) SSD capacity 256 GB Read speed 540 MB/s Write speed 500 MB/s Memory type TLC Random write (4KB) 88000 IOPS Random read (4KB) 97000 IOPS Data transfer rate 6 Gbit/s Design Component for PC SSD form factor M.2 Features Interface Serial ATA III Component for PC NAND flash type TLC (Triple Level Cell) SSD capacity 256 GB Read speed 540 MB/s Write speed 500 MB/s Memory type TLC Random write (4KB) 88000 IOPS Random read (4KB) 97000 IOPS Data transfer rate 6 Gbit/s SSD form factor M.2 Harmonized System (HS) code 84717070 Technical details Interface Serial ATA III SSD form factor M.2 Logistics data Harmonized System (HS) code 84717070
Samsung PM871b M.2 256 GB Serial ATA III TLC Hard drive SSD capacity 256 GB Memory type TLC Data transmission Read speed 540 MB/s Write speed 500 MB/s Random write (4KB) 88000 IOPS Random read (4KB) 97000 IOPS Data transfer rate 6 Gbit/s Performance Interface Serial ATA III Component for PC NAND flash type TLC (Triple Level Cell) SSD capacity 256 GB Read speed 540 MB/s Write speed 500 MB/s Memory type TLC Random write (4KB) 88000 IOPS Random read (4KB) 97000 IOPS Data transfer rate 6 Gbit/s Design Component for PC SSD form factor M.2 Features Interface Serial ATA III Component for PC NAND flash type TLC (Triple Level Cell) SSD capacity 256 GB Read speed 540 MB/s Write speed 500 MB/s Memory type TLC Random write (4KB) 88000 IOPS Random read (4KB) 97000 IOPS Data transfer rate 6 Gbit/s SSD form factor M.2 Harmonized System (HS) code 84717070 Technical details Interface Serial ATA III SSD form factor M.2 Logistics data Harmonized System (HS) code 84717070
£37.22
£31.02 In stock
Hard drive SSD capacity 480 GB Memory type TLC Performance Intel® Smart Response Technology No Intel® Rapid Start Technology No Intel High Endurance Technology (HET) No Interface Serial ATA III Component for Server/workstation SSD ARK ID 120521 NVMe No End-to-End Data Protection Yes SSD capacity 480 GB Security algorithms 256-bit AES Read speed 500 MB/s Write speed 330 MB/s Memory type TLC Uncorrectable Bit Error Rate (UBER) < 1 per 10^17 bits read SSD temperature monitoring Yes Random write (100% span) 20000 IOPS Random read (100% span) 72000 IOPS Mean time between failures (MTBF) 2000000 h Write latency 36 µs Read latency 36 µs Hardware encryption Yes Enhanced Power Loss Data Protection technology Yes Data transfer rate 6 Gbit/s Compatible products Server Board S7200AP Server Board S7200APL Server Board S2600BPB Server Board S2600BPQ Server Board S2600BPS Server Board S2600CW2R Server Board S2600CW2SR Server Board S2600CWTR Server Board S2600CWTSR Server Board S2600KPR Server Board S2600KPFR Server Board S2600KPTR Server Board S2600STB Server Board S2600STQ Server Board S2600TPFR Server Board S2600TPNR Server Board S2600TPR Server Board S2600WF0 Server Board S2600WFT Server Board S2600WTTR Server Board S2600WT2R Server Board S2600WTTS1R Compute Module HNS2600BPB24 Compute Module HNS2600BPB Compute Module HNS2600BPQ Compute Module HNS2600BPQ24 Compute Module HNS2600BPS Compute Module HNS2600BPS24 Compute Module HNS2600KPFR Compute Module HNS2600KPR Compute Module HNS2600TP24R Compute Module HNS2600TP24SR Compute Module HNS2600TP24STR Compute Module HNS2600TPFR Compute Module HNS2600TPNR Compute Module HNS2600TPR Compute Module HNS7200AP Compute Module HNS7200APL Server System R1208WFTYS Server System R1304WF0YS Server System R1304WFTYS Server System R1208WT2GSR Server System R1208WTTGSR Server System R1304WT2GSR Server System R1304WTTGSR Server System R2208WF0ZS Server System R2208WFTZS Server System R2224WFTZS Server System R2308WFTZS Server System R2312WF0NP Server System R2312WFTZS Server System R2208WTTYSR Server System R2208WT2YSR Server System R2208WTTYC1R Server System R2308WTTYSR Server System R2312WTTYSR Server System R2224WTTYSR Data transmission Read speed 500 MB/s Write speed 330 MB/s Random write (100% span) 20000 IOPS Random read (100% span) 72000 IOPS Write latency 36 µs Read latency 36 µs Data transfer rate 6 Gbit/s Security Security algorithms 256-bit AES Endurance Uncorrectable Bit Error Rate (UBER) < 1 per 10^17 bits read Mean time between failures (MTBF) 2000000 h Design Component for Server/workstation Product colour Silver SSD form factor 2.5" Product family Data center SSD Product series Intel® SSD DC S4500 Series Product codename Youngsville Features Interface Serial ATA III Component for Server/workstation SSD ARK ID 120521 NVMe No End-to-End Data Protection Yes SSD capacity 480 GB Security algorithms 256-bit AES Read speed 500 MB/s Write speed 330 MB/s Memory type TLC Uncorrectable Bit Error Rate (UBER) < 1 per 10^17 bits read SSD temperature monitoring Yes Random write (100% span) 20000 IOPS Random read (100% span) 72000 IOPS Mean time between failures (MTBF) 2000000 h Write latency 36 µs Read latency 36 µs Hardware encryption Yes Enhanced Power Loss Data Protection technology Yes Data transfer rate 6 Gbit/s SSD form factor 2.5" Compatible products Server Board S7200AP Server Board S7200APL Server Board S2600BPB Server Board S2600BPQ Server Board S2600BPS Server Board S2600CW2R Server Board S2600CW2SR Server Board S2600CWTR Server Board S2600CWTSR Server Board S2600KPR Server Board S2600KPFR Server Board S2600KPTR Server Board S2600STB Server Board S2600STQ Server Board S2600TPFR Server Board S2600TPNR Server Board S2600TPR Server Board S2600WF0 Server Board S2600WFT Server Board S2600WTTR Server Board S2600WT2R Server Board S2600WTTS1R Compute Module HNS2600BPB24 Compute Module HNS2600BPB Compute Module HNS2600BPQ Compute Module HNS2600BPQ24 Compute Module HNS2600BPS Compute Module HNS2600BPS24 Compute Module HNS2600KPFR Compute Module HNS2600KPR Compute Module HNS2600TP24R Compute Module HNS2600TP24SR Compute Module HNS2600TP24STR Compute Module HNS2600TPFR Compute Module HNS2600TPNR Compute Module HNS2600TPR Compute Module HNS7200AP Compute Module HNS7200APL Server System R1208WFTYS Server System R1304WF0YS Server System R1304WFTYS Server System R1208WT2GSR Server System R1208WTTGSR Server System R1304WT2GSR Server System R1304WTTGSR Server System R2208WF0ZS Server System R2208WFTZS Server System R2224WFTZS Server System R2308WFTZS Server System R2312WF0NP Server System R2312WFTZS Server System R2208WTTYSR Server System R2208WT2YSR Server System R2208WTTYC1R Server System R2308WTTYSR Server System R2312WTTYSR Server System R2224WTTYSR Harmonized System (HS) code 84717070 Power Power consumption (idle) 0.9 W Brand-specific features Intel® Smart Response Technology No Intel® Rapid Start Technology No Intel High Endurance Technology (HET) No Product family Data center SSD Product series Intel® SSD DC S4500 Series Product codename Youngsville Operational conditions Operating temperature (T-T) 0 - 70 °C Operating shock 1000 G Non-operating shock 1000 G Operating vibration 2.17 G Non-operating vibration 3.13 G Technical details Interface Serial ATA III Operating temperature (T-T) 0 - 70 °C Operating shock 1000 G Non-operating shock 1000 G Operating vibration 2.17 G Non-operating vibration 3.13 G SSD temperature monitoring Yes Intel High Endurance Technology (HET) No Hardware encryption Yes Enhanced Power Loss Data Protection technology Yes Product colour Silver SSD form factor 2.5" Status End of Life SSD power consumption (active) 3.6W SSD endurance rating 0.90 PBW Launch date Q3'17 Weight & dimensions Height 7 mm Logistics data Harmonized System (HS) code 84717070 Other features Uncorrectable Bit Error Rate (UBER) < 1 per 10^17 bits read Product colour Silver Status End of Life SSD power consumption (active) 3.6W SSD endurance rating 0.90 PBW Launch date Q3'17 Product family Data center SSD Product series Intel® SSD DC S4500 Series Product codename Youngsville
Intel DC S4500 2.5" 480 GB Serial ATA III TLC Hard drive SSD capacity 480 GB Memory type TLC Performance Intel® Smart Response Technology No Intel® Rapid Start Technology No Intel High Endurance Technology (HET) No Interface Serial ATA III Component for Server/workstation SSD ARK ID 120521 NVMe No End-to-End Data Protection Yes SSD capacity 480 GB Security algorithms 256-bit AES Read speed 500 MB/s Write speed 330 MB/s Memory type TLC Uncorrectable Bit Error Rate (UBER) < 1 per 10^17 bits read SSD temperature monitoring Yes Random write (100% span) 20000 IOPS Random read (100% span) 72000 IOPS Mean time between failures (MTBF) 2000000 h Write latency 36 µs Read latency 36 µs Hardware encryption Yes Enhanced Power Loss Data Protection technology Yes Data transfer rate 6 Gbit/s Compatible products Server Board S7200AP Server Board S7200APL Server Board S2600BPB Server Board S2600BPQ Server Board S2600BPS Server Board S2600CW2R Server Board S2600CW2SR Server Board S2600CWTR Server Board S2600CWTSR Server Board S2600KPR Server Board S2600KPFR Server Board S2600KPTR Server Board S2600STB Server Board S2600STQ Server Board S2600TPFR Server Board S2600TPNR Server Board S2600TPR Server Board S2600WF0 Server Board S2600WFT Server Board S2600WTTR Server Board S2600WT2R Server Board S2600WTTS1R Compute Module HNS2600BPB24 Compute Module HNS2600BPB Compute Module HNS2600BPQ Compute Module HNS2600BPQ24 Compute Module HNS2600BPS Compute Module HNS2600BPS24 Compute Module HNS2600KPFR Compute Module HNS2600KPR Compute Module HNS2600TP24R Compute Module HNS2600TP24SR Compute Module HNS2600TP24STR Compute Module HNS2600TPFR Compute Module HNS2600TPNR Compute Module HNS2600TPR Compute Module HNS7200AP Compute Module HNS7200APL Server System R1208WFTYS Server System R1304WF0YS Server System R1304WFTYS Server System R1208WT2GSR Server System R1208WTTGSR Server System R1304WT2GSR Server System R1304WTTGSR Server System R2208WF0ZS Server System R2208WFTZS Server System R2224WFTZS Server System R2308WFTZS Server System R2312WF0NP Server System R2312WFTZS Server System R2208WTTYSR Server System R2208WT2YSR Server System R2208WTTYC1R Server System R2308WTTYSR Server System R2312WTTYSR Server System R2224WTTYSR Data transmission Read speed 500 MB/s Write speed 330 MB/s Random write (100% span) 20000 IOPS Random read (100% span) 72000 IOPS Write latency 36 µs Read latency 36 µs Data transfer rate 6 Gbit/s Security Security algorithms 256-bit AES Endurance Uncorrectable Bit Error Rate (UBER) < 1 per 10^17 bits read Mean time between failures (MTBF) 2000000 h Design Component for Server/workstation Product colour Silver SSD form factor 2.5" Product family Data center SSD Product series Intel® SSD DC S4500 Series Product codename Youngsville Features Interface Serial ATA III Component for Server/workstation SSD ARK ID 120521 NVMe No End-to-End Data Protection Yes SSD capacity 480 GB Security algorithms 256-bit AES Read speed 500 MB/s Write speed 330 MB/s Memory type TLC Uncorrectable Bit Error Rate (UBER) < 1 per 10^17 bits read SSD temperature monitoring Yes Random write (100% span) 20000 IOPS Random read (100% span) 72000 IOPS Mean time between failures (MTBF) 2000000 h Write latency 36 µs Read latency 36 µs Hardware encryption Yes Enhanced Power Loss Data Protection technology Yes Data transfer rate 6 Gbit/s SSD form factor 2.5" Compatible products Server Board S7200AP Server Board S7200APL Server Board S2600BPB Server Board S2600BPQ Server Board S2600BPS Server Board S2600CW2R Server Board S2600CW2SR Server Board S2600CWTR Server Board S2600CWTSR Server Board S2600KPR Server Board S2600KPFR Server Board S2600KPTR Server Board S2600STB Server Board S2600STQ Server Board S2600TPFR Server Board S2600TPNR Server Board S2600TPR Server Board S2600WF0 Server Board S2600WFT Server Board S2600WTTR Server Board S2600WT2R Server Board S2600WTTS1R Compute Module HNS2600BPB24 Compute Module HNS2600BPB Compute Module HNS2600BPQ Compute Module HNS2600BPQ24 Compute Module HNS2600BPS Compute Module HNS2600BPS24 Compute Module HNS2600KPFR Compute Module HNS2600KPR Compute Module HNS2600TP24R Compute Module HNS2600TP24SR Compute Module HNS2600TP24STR Compute Module HNS2600TPFR Compute Module HNS2600TPNR Compute Module HNS2600TPR Compute Module HNS7200AP Compute Module HNS7200APL Server System R1208WFTYS Server System R1304WF0YS Server System R1304WFTYS Server System R1208WT2GSR Server System R1208WTTGSR Server System R1304WT2GSR Server System R1304WTTGSR Server System R2208WF0ZS Server System R2208WFTZS Server System R2224WFTZS Server System R2308WFTZS Server System R2312WF0NP Server System R2312WFTZS Server System R2208WTTYSR Server System R2208WT2YSR Server System R2208WTTYC1R Server System R2308WTTYSR Server System R2312WTTYSR Server System R2224WTTYSR Harmonized System (HS) code 84717070 Power Power consumption (idle) 0.9 W Brand-specific features Intel® Smart Response Technology No Intel® Rapid Start Technology No Intel High Endurance Technology (HET) No Product family Data center SSD Product series Intel® SSD DC S4500 Series Product codename Youngsville Operational conditions Operating temperature (T-T) 0 - 70 °C Operating shock 1000 G Non-operating shock 1000 G Operating vibration 2.17 G Non-operating vibration 3.13 G Technical details Interface Serial ATA III Operating temperature (T-T) 0 - 70 °C Operating shock 1000 G Non-operating shock 1000 G Operating vibration 2.17 G Non-operating vibration 3.13 G SSD temperature monitoring Yes Intel High Endurance Technology (HET) No Hardware encryption Yes Enhanced Power Loss Data Protection technology Yes Product colour Silver SSD form factor 2.5" Status End of Life SSD power consumption (active) 3.6W SSD endurance rating 0.90 PBW Launch date Q3'17 Weight & dimensions Height 7 mm Logistics data Harmonized System (HS) code 84717070 Other features Uncorrectable Bit Error Rate (UBER) < 1 per 10^17 bits read Product colour Silver Status End of Life SSD power consumption (active) 3.6W SSD endurance rating 0.90 PBW Launch date Q3'17 Product family Data center SSD Product series Intel® SSD DC S4500 Series Product codename Youngsville
£379.61
£316.34 Out of stock
<