Get 5% Off Your Order When You Leave us a 5 Star Review, Let us Know Your Experience Here
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 700 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 5% |
Output power capacity | 1 kVA |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Battery | |
Battery type | AGM |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
LED indicators | Yes |
Surge protection | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Maintenance-free | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 700 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Output voltage Total Harmonic Distortion (THD) | 5% |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Output power capacity | 1 kVA |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Maintenance-free | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
SmartSlot | Yes |
AC outlets quantity | 6 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 6 |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Safety | EN 62040-1 |
Cooling type | Active |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 11.4 kg |
Width | 140 mm |
Height | 191 mm |
Depth | 327 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Battery type | AGM |
Compatible operating systems | Windows, Linux, Mac |
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 700 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 5% |
Output power capacity | 1 kVA |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Battery | |
Battery type | AGM |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
LED indicators | Yes |
Surge protection | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Maintenance-free | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 700 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Output voltage Total Harmonic Distortion (THD) | 5% |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Output power capacity | 1 kVA |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Maintenance-free | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
SmartSlot | Yes |
AC outlets quantity | 6 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 6 |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Safety | EN 62040-1 |
Cooling type | Active |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 11.4 kg |
Width | 140 mm |
Height | 191 mm |
Depth | 327 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Battery type | AGM |
Compatible operating systems | Windows, Linux, Mac |
Save £197.42
Power | |
---|---|
Output power | 600 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Output power capacity | 1 kVA |
Efficiency (On-line mode) | 95% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Total Harmonic Distortion (THD) (linear load) | 5% |
Total Harmonic Distortion (THD) (non-linear load) | 10% |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 40 dB |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Charge type | Constant current/Constant voltage |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 600 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 40 dB |
Output power capacity | 1 kVA |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Efficiency (On-line mode) | 95% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Total Harmonic Distortion (THD) (linear load) | 5% |
Total Harmonic Distortion (THD) (non-linear load) | 10% |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
SmartSlot | Yes |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
RS-232 ports | 1 |
Battery | |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 4 h |
Cold start | Yes |
Automatic battery test | Yes |
Charge type | Constant current/Constant voltage |
Design | |
Rack capacity | 1U |
Form factor | Rackmount |
Product colour | Black |
Safety | EN 62040-1 |
Certification | EN 62040-2(C2), EN 62040-3, ISO-9001, ISO-14001 |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions | |
Weight | 14.2 kg |
Width | 433 mm |
Height | 44 mm |
Depth | 485 mm |
Packaging data | |
Fuse included | Yes |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1 |
Certification | EN 62040-2(C2), EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Compatible operating systems | Windows, Linux, Mac |
Packaging content | |
Fuse included | Yes |
Power | |
---|---|
Output power | 600 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Output power capacity | 1 kVA |
Efficiency (On-line mode) | 95% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Total Harmonic Distortion (THD) (linear load) | 5% |
Total Harmonic Distortion (THD) (non-linear load) | 10% |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 40 dB |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Charge type | Constant current/Constant voltage |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 600 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 40 dB |
Output power capacity | 1 kVA |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Efficiency (On-line mode) | 95% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Total Harmonic Distortion (THD) (linear load) | 5% |
Total Harmonic Distortion (THD) (non-linear load) | 10% |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
SmartSlot | Yes |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
RS-232 ports | 1 |
Battery | |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 4 h |
Cold start | Yes |
Automatic battery test | Yes |
Charge type | Constant current/Constant voltage |
Design | |
Rack capacity | 1U |
Form factor | Rackmount |
Product colour | Black |
Safety | EN 62040-1 |
Certification | EN 62040-2(C2), EN 62040-3, ISO-9001, ISO-14001 |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions | |
Weight | 14.2 kg |
Width | 433 mm |
Height | 44 mm |
Depth | 485 mm |
Packaging data | |
Fuse included | Yes |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1 |
Certification | EN 62040-2(C2), EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Compatible operating systems | Windows, Linux, Mac |
Packaging content | |
Fuse included | Yes |
Save £334.62
Power | |
---|---|
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 630 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 2% |
Input current Total Harmonic Distortion (THD) | 2% |
Output power capacity | 0.7 kVA |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Battery | |
Battery type | AGM |
Off-mode charging | Yes |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 4 h |
Automatic battery test | Yes |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Off-mode charging | Yes |
Number of output phases | 1 |
Number of input phases | 1 |
LED indicators | Battery replacement |
Surge protection | Yes |
Power protection features | Short circuit, Under current, Under voltage |
Noise level | 49 dB |
Audible alarm(s) | Yes |
Overload capacity (1 minute) | 130% |
Features | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Number of output phases | 1 |
Number of input phases | 1 |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 630 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Short circuit, Under current, Under voltage |
Output voltage Total Harmonic Distortion (THD) | 2% |
Noise level | 49 dB |
Input current Total Harmonic Distortion (THD) | 2% |
Audible alarm(s) | Yes |
Output power capacity | 0.7 kVA |
Overload capacity (1 minute) | 130% |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Number of type F outputs | 3 |
AC outlets quantity | 3 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
Design | |
Form factor | Tower |
LED indicators | Battery replacement |
Product colour | Black |
Safety | EN 62040-1:2008+A1:2013 |
Cooling type | Active |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 5000 m |
Technical details | |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 9.2 kg |
Width | 144 mm |
Height | 228 mm |
Depth | 356 mm |
Certificates | |
Safety | EN 62040-1:2008+A1:2013 |
Other features | |
Battery type | AGM |
Power | |
---|---|
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 630 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 2% |
Input current Total Harmonic Distortion (THD) | 2% |
Output power capacity | 0.7 kVA |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Battery | |
Battery type | AGM |
Off-mode charging | Yes |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 4 h |
Automatic battery test | Yes |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Off-mode charging | Yes |
Number of output phases | 1 |
Number of input phases | 1 |
LED indicators | Battery replacement |
Surge protection | Yes |
Power protection features | Short circuit, Under current, Under voltage |
Noise level | 49 dB |
Audible alarm(s) | Yes |
Overload capacity (1 minute) | 130% |
Features | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Number of output phases | 1 |
Number of input phases | 1 |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 630 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Short circuit, Under current, Under voltage |
Output voltage Total Harmonic Distortion (THD) | 2% |
Noise level | 49 dB |
Input current Total Harmonic Distortion (THD) | 2% |
Audible alarm(s) | Yes |
Output power capacity | 0.7 kVA |
Overload capacity (1 minute) | 130% |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Number of type F outputs | 3 |
AC outlets quantity | 3 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
Design | |
Form factor | Tower |
LED indicators | Battery replacement |
Product colour | Black |
Safety | EN 62040-1:2008+A1:2013 |
Cooling type | Active |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 5000 m |
Technical details | |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 9.2 kg |
Width | 144 mm |
Height | 228 mm |
Depth | 356 mm |
Certificates | |
Safety | EN 62040-1:2008+A1:2013 |
Other features | |
Battery type | AGM |
Save £220.92
Power | |
---|---|
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 900 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 2% |
Input current Total Harmonic Distortion (THD) | 2% |
Output power capacity | 1 kVA |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Battery | |
Battery type | AGM |
Off-mode charging | Yes |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 4 h |
Automatic battery test | Yes |
Performance | |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Off-mode charging | Yes |
Number of output phases | 1 |
Number of input phases | 1 |
LED indicators | Battery replacement |
Surge protection | Yes |
Power protection features | Over current, Short circuit, Under current, Under voltage |
Noise level | 49 dB |
Audible alarm(s) | Yes |
Overload capacity (1 minute) | 130% |
Features | |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Number of output phases | 1 |
Number of input phases | 1 |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 900 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Over current, Short circuit, Under current, Under voltage |
Output voltage Total Harmonic Distortion (THD) | 2% |
Noise level | 49 dB |
Input current Total Harmonic Distortion (THD) | 2% |
Audible alarm(s) | Yes |
Output power capacity | 1 kVA |
Overload capacity (1 minute) | 130% |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Number of type F outputs | 3 |
AC outlets quantity | 3 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
Design | |
Form factor | Tower |
LED indicators | Battery replacement |
Product colour | Black |
Safety | EN 62040-1:2008+A1:2013 |
Cooling type | Active |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 5000 m |
Technical details | |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Weight & dimensions | |
Weight | 10.2 kg |
Width | 144 mm |
Height | 228 mm |
Depth | 356 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1:2008+A1:2013 |
Other features | |
Battery type | AGM |
Power | |
---|---|
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 900 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 2% |
Input current Total Harmonic Distortion (THD) | 2% |
Output power capacity | 1 kVA |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Battery | |
Battery type | AGM |
Off-mode charging | Yes |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 4 h |
Automatic battery test | Yes |
Performance | |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Off-mode charging | Yes |
Number of output phases | 1 |
Number of input phases | 1 |
LED indicators | Battery replacement |
Surge protection | Yes |
Power protection features | Over current, Short circuit, Under current, Under voltage |
Noise level | 49 dB |
Audible alarm(s) | Yes |
Overload capacity (1 minute) | 130% |
Features | |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Number of output phases | 1 |
Number of input phases | 1 |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 900 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Over current, Short circuit, Under current, Under voltage |
Output voltage Total Harmonic Distortion (THD) | 2% |
Noise level | 49 dB |
Input current Total Harmonic Distortion (THD) | 2% |
Audible alarm(s) | Yes |
Output power capacity | 1 kVA |
Overload capacity (1 minute) | 130% |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Number of type F outputs | 3 |
AC outlets quantity | 3 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
Design | |
Form factor | Tower |
LED indicators | Battery replacement |
Product colour | Black |
Safety | EN 62040-1:2008+A1:2013 |
Cooling type | Active |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 5000 m |
Technical details | |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Weight & dimensions | |
Weight | 10.2 kg |
Width | 144 mm |
Height | 228 mm |
Depth | 356 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1:2008+A1:2013 |
Other features | |
Battery type | AGM |
Save £266.66
Power | |
---|---|
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 630 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 2% |
Input current Total Harmonic Distortion (THD) | 2% |
Output power capacity | 0.7 kVA |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Battery | |
Battery type | AGM |
Off-mode charging | Yes |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 4 h |
Automatic battery test | Yes |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Off-mode charging | Yes |
Number of output phases | 1 |
Number of input phases | 1 |
LED indicators | Battery replacement |
Surge protection | Yes |
Power protection features | Over current, Short circuit, Under current, Under voltage |
Noise level | 49 dB |
Audible alarm(s) | Yes |
Overload capacity (1 minute) | 130% |
Features | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Number of output phases | 1 |
Number of input phases | 1 |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 630 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Over current, Short circuit, Under current, Under voltage |
Output voltage Total Harmonic Distortion (THD) | 2% |
Noise level | 49 dB |
Input current Total Harmonic Distortion (THD) | 2% |
Audible alarm(s) | Yes |
Output power capacity | 0.7 kVA |
Overload capacity (1 minute) | 130% |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | C13 coupler, IEC Jumpers |
Power plug | C19 coupler |
USB 2.0 ports quantity | 1 |
Number of output IEC jumpers | 4 |
Design | |
Form factor | Tower |
LED indicators | Battery replacement |
Product colour | Black |
Safety | EN 62040-1:2008+A1:2013 |
Cooling type | Active |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 5000 m |
Technical details | |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 9.2 kg |
Width | 144 mm |
Height | 228 mm |
Depth | 356 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1:2008+A1:2013 |
Other features | |
Battery type | AGM |
Power | |
---|---|
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 630 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 2% |
Input current Total Harmonic Distortion (THD) | 2% |
Output power capacity | 0.7 kVA |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Battery | |
Battery type | AGM |
Off-mode charging | Yes |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 4 h |
Automatic battery test | Yes |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Off-mode charging | Yes |
Number of output phases | 1 |
Number of input phases | 1 |
LED indicators | Battery replacement |
Surge protection | Yes |
Power protection features | Over current, Short circuit, Under current, Under voltage |
Noise level | 49 dB |
Audible alarm(s) | Yes |
Overload capacity (1 minute) | 130% |
Features | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm, Battery replacement |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Output voltage regulation | 1% |
Output frequency regulation | 0.05 Hz |
Number of output phases | 1 |
Number of input phases | 1 |
Output power factor | 0.9 |
Input power factor | 0.99 |
Output power | 630 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Over current, Short circuit, Under current, Under voltage |
Output voltage Total Harmonic Distortion (THD) | 2% |
Noise level | 49 dB |
Input current Total Harmonic Distortion (THD) | 2% |
Audible alarm(s) | Yes |
Output power capacity | 0.7 kVA |
Overload capacity (1 minute) | 130% |
Efficiency (On-line mode) | 92% |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | C13 coupler, IEC Jumpers |
Power plug | C19 coupler |
USB 2.0 ports quantity | 1 |
Number of output IEC jumpers | 4 |
Design | |
Form factor | Tower |
LED indicators | Battery replacement |
Product colour | Black |
Safety | EN 62040-1:2008+A1:2013 |
Cooling type | Active |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 5000 m |
Technical details | |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 9.2 kg |
Width | 144 mm |
Height | 228 mm |
Depth | 356 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1:2008+A1:2013 |
Other features | |
Battery type | AGM |
Save £168.70
Power | |
---|---|
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.1 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.1 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 8.2 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Power | |
---|---|
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.1 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.1 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 8.2 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Save £89.81
Power | |
---|---|
Output voltage regulation | 1% |
Output power | 1000 W |
Input operation voltage (min) | 200 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Emergency Power Off (EPO) | Yes |
Power factor | 1 |
Output voltage Total Harmonic Distortion (THD) | 5% |
Input current Total Harmonic Distortion (THD) | 5% |
Output power capacity | 3 kVA |
Efficiency (On-line mode) | 93% |
Charging current | 1.5 A |
Efficiency (ECO mode) | 97% |
ECO mode | Yes |
Performance | |
UPS topology | Double-conversion (Online) |
Noise level | 45 dB |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Double-conversion (Online) |
Output voltage regulation | 1% |
Output power | 1000 W |
Input operation voltage (min) | 200 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Emergency Power Off (EPO) | Yes |
Power factor | 1 |
Output voltage Total Harmonic Distortion (THD) | 5% |
Noise level | 45 dB |
Input current Total Harmonic Distortion (THD) | 5% |
Output power capacity | 3 kVA |
Efficiency (On-line mode) | 93% |
Efficiency (ECO mode) | 97% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Carrying handle(s) | No |
Compatibility | Software for Windows, Linux and Mac/app for iOS and Android/web portal |
Charging current | 1.5 A |
Ports & interfaces | |
USB port | Yes |
AC outlet types | C19 coupler |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Ethernet LAN (RJ-45) ports | 1 |
Battery | |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 3 h |
Cold start | Yes |
Charging current | 1.5 A |
Design | |
Form factor | Rackmount/Tower |
Compatibility | Software for Windows, Linux and Mac/app for iOS and Android/web portal |
Product colour | Black |
Safety | EN IEC 62040-2(C2), EN IEC 62040-1, VFI-SS-31 (EN 62040-3) |
Certification | ISO 9001, ISO 14001, ISO 45001 |
Operational conditions | |
Operating temperature (T-T) | 0 - 50 °C |
Operating relative humidity (H-H) | 0 - 95% |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 14 kg |
Width | 438 mm |
Height | 86 mm |
Depth | 445 mm |
Certificates | |
Safety | EN IEC 62040-2(C2), EN IEC 62040-1, VFI-SS-31 (EN 62040-3) |
Certification | ISO 9001, ISO 14001, ISO 45001 |
Power | |
---|---|
Output voltage regulation | 1% |
Output power | 1000 W |
Input operation voltage (min) | 200 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Emergency Power Off (EPO) | Yes |
Power factor | 1 |
Output voltage Total Harmonic Distortion (THD) | 5% |
Input current Total Harmonic Distortion (THD) | 5% |
Output power capacity | 3 kVA |
Efficiency (On-line mode) | 93% |
Charging current | 1.5 A |
Efficiency (ECO mode) | 97% |
ECO mode | Yes |
Performance | |
UPS topology | Double-conversion (Online) |
Noise level | 45 dB |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Double-conversion (Online) |
Output voltage regulation | 1% |
Output power | 1000 W |
Input operation voltage (min) | 200 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Emergency Power Off (EPO) | Yes |
Power factor | 1 |
Output voltage Total Harmonic Distortion (THD) | 5% |
Noise level | 45 dB |
Input current Total Harmonic Distortion (THD) | 5% |
Output power capacity | 3 kVA |
Efficiency (On-line mode) | 93% |
Efficiency (ECO mode) | 97% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Carrying handle(s) | No |
Compatibility | Software for Windows, Linux and Mac/app for iOS and Android/web portal |
Charging current | 1.5 A |
Ports & interfaces | |
USB port | Yes |
AC outlet types | C19 coupler |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Ethernet LAN (RJ-45) ports | 1 |
Battery | |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 3 h |
Cold start | Yes |
Charging current | 1.5 A |
Design | |
Form factor | Rackmount/Tower |
Compatibility | Software for Windows, Linux and Mac/app for iOS and Android/web portal |
Product colour | Black |
Safety | EN IEC 62040-2(C2), EN IEC 62040-1, VFI-SS-31 (EN 62040-3) |
Certification | ISO 9001, ISO 14001, ISO 45001 |
Operational conditions | |
Operating temperature (T-T) | 0 - 50 °C |
Operating relative humidity (H-H) | 0 - 95% |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 14 kg |
Width | 438 mm |
Height | 86 mm |
Depth | 445 mm |
Certificates | |
Safety | EN IEC 62040-2(C2), EN IEC 62040-1, VFI-SS-31 (EN 62040-3) |
Certification | ISO 9001, ISO 14001, ISO 45001 |
Save £518.90
Power | |
---|---|
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.5 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.5 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Cooling type | Active |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Built-in fan | Yes |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 10.4 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Power | |
---|---|
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.5 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.5 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Cooling type | Active |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Built-in fan | Yes |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 10.4 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Save £113.24
Power | |
---|---|
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.5 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.5 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Detachable power cord | Yes |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 6 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Cooling type | Active |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Built-in fan | Yes |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 10.4 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Power | |
---|---|
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.5 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.5 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Detachable power cord | Yes |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 6 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Cooling type | Active |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Built-in fan | Yes |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 10.4 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Save £100.89
Power | |
---|---|
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.1 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.1 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Detachable power cord | Yes |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 6 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 8.2 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Power | |
---|---|
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.1 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.1 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Detachable power cord | Yes |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 6 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 8.2 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Save £72.71
Save £6.18