Get 5% Off Your Order When You Leave us a 5 Star Review, Let us Know Your Experience Here
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 2100 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 5% |
Output power capacity | 3 kVA |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Battery | |
Battery type | AGM |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
LED indicators | Yes |
Surge protection | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Maintenance-free | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 2100 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Output voltage Total Harmonic Distortion (THD) | 5% |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Output power capacity | 3 kVA |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Maintenance-free | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
SmartSlot | Yes |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | C13 coupler, Terminal |
Power plug | C14 coupler |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 4 |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Safety | EN 62040-1 |
Cooling type | Active |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 29.7 kg |
Width | 196 mm |
Height | 342 mm |
Depth | 416 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Battery type | AGM |
Compatible operating systems | Windows, Linux, Mac |
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 2100 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 5% |
Output power capacity | 3 kVA |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Battery | |
Battery type | AGM |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
LED indicators | Yes |
Surge protection | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Maintenance-free | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 2100 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Output voltage Total Harmonic Distortion (THD) | 5% |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Output power capacity | 3 kVA |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Maintenance-free | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
SmartSlot | Yes |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | C13 coupler, Terminal |
Power plug | C14 coupler |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 4 |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Safety | EN 62040-1 |
Cooling type | Active |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 29.7 kg |
Width | 196 mm |
Height | 342 mm |
Depth | 416 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Battery type | AGM |
Compatible operating systems | Windows, Linux, Mac |
Save £352.02
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 1400 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 5% |
Output power capacity | 2 kVA |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Battery | |
Battery type | AGM |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
LED indicators | Yes |
Surge protection | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Maintenance-free | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 1400 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Output voltage Total Harmonic Distortion (THD) | 5% |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Output power capacity | 2 kVA |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Maintenance-free | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
SmartSlot | Yes |
AC outlets quantity | 6 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 6 |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Safety | EN 62040-1 |
Cooling type | Active |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 14.2 kg |
Width | 140 mm |
Height | 191 mm |
Depth | 327 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Battery type | AGM |
Compatible operating systems | Windows, Linux, Mac |
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 1400 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 5% |
Output power capacity | 2 kVA |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Battery | |
Battery type | AGM |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
LED indicators | Yes |
Surge protection | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Maintenance-free | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 1400 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Output voltage Total Harmonic Distortion (THD) | 5% |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Output power capacity | 2 kVA |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Maintenance-free | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
SmartSlot | Yes |
AC outlets quantity | 6 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 6 |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Safety | EN 62040-1 |
Cooling type | Active |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 14.2 kg |
Width | 140 mm |
Height | 191 mm |
Depth | 327 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Battery type | AGM |
Compatible operating systems | Windows, Linux, Mac |
Save £166.26
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 700 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 5% |
Output power capacity | 1 kVA |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Battery | |
Battery type | AGM |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
LED indicators | Yes |
Surge protection | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Maintenance-free | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 700 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Output voltage Total Harmonic Distortion (THD) | 5% |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Output power capacity | 1 kVA |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Maintenance-free | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
SmartSlot | Yes |
AC outlets quantity | 6 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 6 |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Safety | EN 62040-1 |
Cooling type | Active |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 11.4 kg |
Width | 140 mm |
Height | 191 mm |
Depth | 327 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Battery type | AGM |
Compatible operating systems | Windows, Linux, Mac |
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 700 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Emergency Power Off (EPO) | Yes |
Output voltage Total Harmonic Distortion (THD) | 5% |
Output power capacity | 1 kVA |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Battery | |
Battery type | AGM |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Performance | |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Automatic Voltage Regulation (AVR) | Yes |
LED indicators | Yes |
Surge protection | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Maintenance-free | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pure sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 700 W |
Input operation voltage (min) | 165 V |
Input operation voltage (max) | 290 V |
Output operation voltage (max) | 230 V |
Efficiency | 98% |
Surge protection | Yes |
Emergency Power Off (EPO) | Yes |
Power protection features | Overdischarge, Overload, Short circuit |
Output voltage Total Harmonic Distortion (THD) | 5% |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Output power capacity | 1 kVA |
Overload capacity - line mode (1 minute) | 110% |
Overload capacity - battery mode (1 minute) | 110% |
Efficiency (Stabiliser mode (AVR)) | 92% |
Efficiency (Battery mode) | 80% |
Maintenance-free | Yes |
Input frequency | 50/60 Hz |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
SmartSlot | Yes |
AC outlets quantity | 6 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 6 |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Safety | EN 62040-1 |
Cooling type | Active |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Built-in fan | Yes |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Weight | 11.4 kg |
Width | 140 mm |
Height | 191 mm |
Depth | 327 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Battery type | AGM |
Compatible operating systems | Windows, Linux, Mac |
Save £209.39
Power | |
---|---|
Output power | 720 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output power capacity | 1.2 kVA |
USB output voltage | 5 V |
USB output current | 2 A |
Performance | |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 720 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Output power capacity | 1.2 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces | |
USB port | Yes |
Number of type F outputs | 4 |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 2 |
Battery | |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Battery recharge time(90%) | 4 h |
Design | |
Form factor | Tower |
Product colour | Red, White |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions | |
Weight | 10.4 kg |
Width | 139 mm |
Height | 195 mm |
Depth | 364 mm |
Certificates | |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Compatible operating systems | Windows, Linux, Mac |
USB output voltage | 5 V |
USB output current | 2 A |
Power | |
---|---|
Output power | 720 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output power capacity | 1.2 kVA |
USB output voltage | 5 V |
USB output current | 2 A |
Performance | |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 720 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Output power capacity | 1.2 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces | |
USB port | Yes |
Number of type F outputs | 4 |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 2 |
Battery | |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Battery recharge time(90%) | 4 h |
Design | |
Form factor | Tower |
Product colour | Red, White |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions | |
Weight | 10.4 kg |
Width | 139 mm |
Height | 195 mm |
Depth | 364 mm |
Certificates | |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Compatible operating systems | Windows, Linux, Mac |
USB output voltage | 5 V |
USB output current | 2 A |
Save £107.01
Power | |
---|---|
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output power capacity | 0.65 kVA |
USB output voltage | 5 V |
USB output current | 2 A |
Performance | |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Output power capacity | 0.65 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces | |
USB port | Yes |
Number of type F outputs | 2 |
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 2 |
Battery | |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Battery recharge time(90%) | 4 h |
Design | |
Form factor | Tower |
Product colour | Red, White |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions | |
Weight | 4.4 kg |
Width | 100 mm |
Height | 143 mm |
Depth | 290 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Compatible operating systems | Windows, Linux, Mac |
USB output voltage | 5 V |
USB output current | 2 A |
Power | |
---|---|
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output power capacity | 0.65 kVA |
USB output voltage | 5 V |
USB output current | 2 A |
Performance | |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Output power capacity | 0.65 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces | |
USB port | Yes |
Number of type F outputs | 2 |
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 2 |
Battery | |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Battery recharge time(90%) | 4 h |
Design | |
Form factor | Tower |
Product colour | Red, White |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions | |
Weight | 4.4 kg |
Width | 100 mm |
Height | 143 mm |
Depth | 290 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Compatible operating systems | Windows, Linux, Mac |
USB output voltage | 5 V |
USB output current | 2 A |
Save £98.37
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 0.7 kVA |
Efficiency (ECO mode) | 95% |
ECO mode | Yes |
Performance | |
Audible alarm modes | Battery replacement, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Auto-restart | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Battery replacement, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Auto-restart | Yes |
Response time | 6 ms |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.7 kVA |
Efficiency (ECO mode) | 95% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Compatibility | Windows, Linux, Unix, Mac |
Ports & interfaces | |
USB port | Yes |
Number of type F outputs | 2 |
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Typical backup time at full load | 20 min |
Cold start | Yes |
Automatic battery test | Yes |
Design | |
Form factor | Tower |
Compatibility | Windows, Linux, Unix, Mac |
LED indicators | Yes |
Product colour | Red, White |
Certification | EN-IEC 62040-1-1, EN-IEC 60950-11, EN-IEC 62040-12, ISO 9001, ISO 14001 |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions | |
Weight | 4.45 kg |
Width | 101 mm |
Height | 142 mm |
Depth | 300 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Certification | EN-IEC 62040-1-1, EN-IEC 60950-11, EN-IEC 62040-12, ISO 9001, ISO 14001 |
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 0.7 kVA |
Efficiency (ECO mode) | 95% |
ECO mode | Yes |
Performance | |
Audible alarm modes | Battery replacement, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Auto-restart | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Battery replacement, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Auto-restart | Yes |
Response time | 6 ms |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.7 kVA |
Efficiency (ECO mode) | 95% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Compatibility | Windows, Linux, Unix, Mac |
Ports & interfaces | |
USB port | Yes |
Number of type F outputs | 2 |
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Typical backup time at full load | 20 min |
Cold start | Yes |
Automatic battery test | Yes |
Design | |
Form factor | Tower |
Compatibility | Windows, Linux, Unix, Mac |
LED indicators | Yes |
Product colour | Red, White |
Certification | EN-IEC 62040-1-1, EN-IEC 60950-11, EN-IEC 62040-12, ISO 9001, ISO 14001 |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions | |
Weight | 4.45 kg |
Width | 101 mm |
Height | 142 mm |
Depth | 300 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Certification | EN-IEC 62040-1-1, EN-IEC 60950-11, EN-IEC 62040-12, ISO 9001, ISO 14001 |
Save £61.39
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.5 kVA |
Efficiency (ECO mode) | 95% |
ECO mode | Yes |
Performance | |
Audible alarm modes | Battery replacement, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Battery replacement, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.5 kVA |
Efficiency (ECO mode) | 95% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Compatibility | Windows, Linux, Unix, Mac |
Ports & interfaces | |
USB port | Yes |
Number of type F outputs | 4 |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Typical backup time at full load | 20 min |
Cold start | Yes |
Automatic battery test | Yes |
Design | |
Form factor | Tower |
Compatibility | Windows, Linux, Unix, Mac |
LED indicators | Yes |
Product colour | Red, White |
Certification | EN-IEC 62040-1-1, EN-IEC 60950-11, EN-IEC 62040-12, ISO 9001, ISO 14001 |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions | |
Weight | 10.4 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 320 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Certification | EN-IEC 62040-1-1, EN-IEC 60950-11, EN-IEC 62040-12, ISO 9001, ISO 14001 |
Power | |
---|---|
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.5 kVA |
Efficiency (ECO mode) | 95% |
ECO mode | Yes |
Performance | |
Audible alarm modes | Battery replacement, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Battery replacement, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Output frequency regulation | 1 Hz |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.5 kVA |
Efficiency (ECO mode) | 95% |
ECO mode | Yes |
Input frequency | 50/60 Hz |
Compatibility | Windows, Linux, Unix, Mac |
Ports & interfaces | |
USB port | Yes |
Number of type F outputs | 4 |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Typical backup time at full load | 20 min |
Cold start | Yes |
Automatic battery test | Yes |
Design | |
Form factor | Tower |
Compatibility | Windows, Linux, Unix, Mac |
LED indicators | Yes |
Product colour | Red, White |
Certification | EN-IEC 62040-1-1, EN-IEC 60950-11, EN-IEC 62040-12, ISO 9001, ISO 14001 |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions | |
Weight | 10.4 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 320 mm |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Certification | EN-IEC 62040-1-1, EN-IEC 60950-11, EN-IEC 62040-12, ISO 9001, ISO 14001 |
Save £152.36
Power | |
---|---|
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output power capacity | 0.65 kVA |
USB output voltage | 5 V |
USB output current | 2 A |
Performance | |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Output power capacity | 0.65 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
USB 2.0 ports quantity | 2 |
Battery | |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Battery recharge time(90%) | 4 h |
Design | |
Form factor | Tower |
Product colour | Red, White |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 4.4 kg |
Width | 100 mm |
Height | 143 mm |
Depth | 290 mm |
Certificates | |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Compatible operating systems | Windows, Unix, Mac |
USB output voltage | 5 V |
USB output current | 2 A |
Power | |
---|---|
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output power capacity | 0.65 kVA |
USB output voltage | 5 V |
USB output current | 2 A |
Performance | |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Power protection features | Battery discharge, Overload, Short circuit |
Noise level | 40 dB |
Output power capacity | 0.65 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
USB 2.0 ports quantity | 2 |
Battery | |
Battery technology | Lead-Calcium (Pb-Ca) |
Cold start | Yes |
Battery recharge time(90%) | 4 h |
Design | |
Form factor | Tower |
Product colour | Red, White |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2400 m |
Technical details | |
Output voltage | 230 V |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 4.4 kg |
Width | 100 mm |
Height | 143 mm |
Depth | 290 mm |
Certificates | |
Safety | EN 62040-1-1; EN-60950-1 |
Certification | EN 62040-2, EN 62040-3, ISO-9001, ISO-14001 |
Other features | |
Output voltage | 230 V |
Compatible operating systems | Windows, Unix, Mac |
USB output voltage | 5 V |
USB output current | 2 A |
Save £114.05
Power | |
---|---|
Output power | 240 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 0.5 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 240 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.5 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 2 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 3.5 kg |
Width | 101 mm |
Height | 142 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Power | |
---|---|
Output power | 240 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 0.5 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 240 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.5 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 2 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 3.5 kg |
Width | 101 mm |
Height | 142 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Save £69.40
Power | |
---|---|
Output power | 240 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 0.5 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 240 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.5 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Detachable power cord | Yes |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 3.5 kg |
Width | 101 mm |
Height | 142 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Power | |
---|---|
Output power | 240 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 0.5 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 240 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.5 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Detachable power cord | Yes |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 3.5 kg |
Width | 101 mm |
Height | 142 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Save £64.06
Power | |
---|---|
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.1 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.1 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 8.2 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Power | |
---|---|
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.1 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 600 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.1 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 8.2 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Save £95.52
Power | |
---|---|
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 0.7 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.7 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 2 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 4.5 kg |
Width | 101 mm |
Height | 142 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Power | |
---|---|
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 0.7 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Pseudo sine |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.7 kVA |
Input frequency | 50/60 Hz |
Power source type | AC |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 2 AC outlet(s) |
USB 2.0 ports quantity | 1 |
USB port type | USB Type-B |
Battery | |
Battery life (max) | 5 year(s) |
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 6 h |
Cold start | Yes |
Design | |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Control type | Buttons |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Weight & dimensions | |
Weight | 4.5 kg |
Width | 101 mm |
Height | 142 mm |
Depth | 300 mm |
Certificates | |
Certification | EN IEC 62040-1 EN IEC 62040-2 EN IEC 62040-3 ISO 9001, ISO 14001, ISO 45001 |
Save £63.04
Save £6.18